王水水浴消解-电感耦合等离子体质谱法测定土壤中的硒

薛静, 安帅, 汪寅夫, 高慧莉, 史佳铭

薛静, 安帅, 汪寅夫, 高慧莉, 史佳铭. 王水水浴消解-电感耦合等离子体质谱法测定土壤中的硒[J]. 岩矿测试, 2020, 39(5): 720-725. DOI: 10.15898/j.cnki.11-2131/td.202003050025
引用本文: 薛静, 安帅, 汪寅夫, 高慧莉, 史佳铭. 王水水浴消解-电感耦合等离子体质谱法测定土壤中的硒[J]. 岩矿测试, 2020, 39(5): 720-725. DOI: 10.15898/j.cnki.11-2131/td.202003050025
XUE Jing, AN Shuai, WANG Yin-fu, GAO Hui-li, SHI Jia-ming. Determination of Selenium in Soil by Inductively Coupled Plasma-Mass Spectrometry with Aqua Regia Digestion in Water Bath[J]. Rock and Mineral Analysis, 2020, 39(5): 720-725. DOI: 10.15898/j.cnki.11-2131/td.202003050025
Citation: XUE Jing, AN Shuai, WANG Yin-fu, GAO Hui-li, SHI Jia-ming. Determination of Selenium in Soil by Inductively Coupled Plasma-Mass Spectrometry with Aqua Regia Digestion in Water Bath[J]. Rock and Mineral Analysis, 2020, 39(5): 720-725. DOI: 10.15898/j.cnki.11-2131/td.202003050025

王水水浴消解-电感耦合等离子体质谱法测定土壤中的硒

详细信息
    作者简介:

    薛静, 硕士, 工程师, 主要从事土壤、岩石矿物等无机元素的分析工作。E-mail:may927@163.com

  • 中图分类号: O657.63;S151.93;O613.52

Determination of Selenium in Soil by Inductively Coupled Plasma-Mass Spectrometry with Aqua Regia Digestion in Water Bath

  • 摘要: 随着富硒产品关注度越来越高,对土壤中硒含量测定的研究也越来越受到人们的重视。应用传统电感耦合等离子体质谱法(ICP-MS)测定土壤样品中的硒时,受到的基体效应和多原子离子干扰比较显著,准确测定硒含量的难度较大。本文建立了采用50%王水-沸水浴消解体系,ICP-MS测定土壤样品中硒含量的方法,实验中采用动能歧视模式(KED)消除质谱干扰,选用103Rh元素作为在线加入内标以消除仪器信号漂移。用该方法对有证土壤标准物质进行分析,其结果均在不确定度范围内,测定值与认定值的相对误差介于-2.01%~2.99%之间,相对标准偏差(RSD)小于6.60%,检出限为0.012μg/g,测定下限为0.048μg/g。应用该方法与国家环境保护标准方法(HJ680—2013)对20个土壤实际样品进行比对分析,其结果基本一致。该方法适合于分析测定地质等行业大批量土壤样品中的硒。
    要点

    (1)将50%王水-沸水浴消解与ICP-MS法相结合测定土壤样品中的硒。

    (2)样品前处理过程一步完成,提高了方法准确性和效率,适合大批量土壤样品中硒的分析。

    (3) 应用动能歧视模式(KED)拓展了ICP-MS在地球化学分析领域的适用范围。

    HIGHLIGHTS

    (1) The 50% aqua regia-boiling water bath digestion combined with ICP-MS method was used to determine selenium in soil samples.

    (2) The sample pretreatment process was completed in one step to improve the accuracy and efficiency of the method and was suitable for the analysis of selenium in large numbers of soil samples.

    (3) The application of kinetic energy discrimination mode (KED) expanded the application scope of ICP-MS in the field of geochemical analysis.

  • 铅锌矿石多以硫化矿共生,或与其他金属共生,组成复合多金属硫化矿床。矿物中伴生的钨、钼、锡、锗、硒、碲等有益组分的含量对矿床的综合评价和矿产工业开发及利用具有重要意义[1]

    对于铅锌矿石的分析,在国家标准方法GB/T 14353—2014中,钨和钼采用氢氟酸-硝酸-高氯酸体系进行样品分解,以电感耦合等离子体质谱仪(ICP-MS)测定,当溶液中共存的铜含量>5%或铅含量>10%时,对钨、钼的测定分别产生不同程度的正、负干扰,该方法通过在标准溶液中等量补偿干扰元素的方式扣除测定干扰。各类地质样品中锡的含量常低于10 μg/g,可采用固体粉末发射光谱法测定[2],但铅锌矿的含硫量高,采用电火花激发时易引起样品飞溅跳样;王铁等[3]采用5种混合酸消解锰铁中的痕量锡,但针对铅锌矿中难熔锡石矿物的分解效果难以保证。国家标准方法中,锗和硒分别以氢氟酸-硝酸-硫酸和碳酸钠-氧化锌进行样品分解,均采用原子荧光光谱法测定,此溶液体系中共存的高含量铅(320 mg/L以上)干扰锗的测定,而硒采用半熔法-沸水提取的前处理方法使进入测定体系的主量金属元素大幅度减少,基本消除了干扰。碲元素的丰度低,熔矿后通常需要分离富集,刘正等[4]采用萃取法进行样品预处理,以石墨炉原子吸收光谱法测定碲的含量。国家标准中采用共沉淀分离的方法,当硒含量高于1 μg/g时可能干扰碲的测定。可见现有分析方法中,对铅锌矿有用组分进行综合评价时各元素采用分组或单独溶矿和测定的方式,多元素无法同时分析,操作强度大、效率低,且存在不可避免的主量元素干扰,影响了分析的准确度和精密度。

    采用ICP-MS测定铅锌矿中的6种伴生元素,研究人员通常采用混酸分组处理样品。为了确保难熔元素锡完全分解,王佳翰等[5]同时使用硫酸和高氯酸高温冒烟消解,再以硝酸180℃复溶样品同时测定钨、钼、锡,样品处理时间长;非金属硒、碲含量较低,且易受主量元素干扰,陈波等[6]采用乙醇介质提高硒、碲的分析灵敏度。现有的熔矿和测定方法难以兼顾6种元素的同时、准确测定。本研究采用碱熔体系,熔矿后加入阳离子树脂交换分离钠盐,同时将造岩元素钾、铁、铝等及主量元素铅、锌从测定体系中分离,有效减小基体效应和矿石中铅的干扰,建立了以ICP-MS测定铅锌矿中的钨、钼、锡、锗、硒、碲的方法。

    iCAP Q型电感耦合等离子体质谱仪(美国ThermoFisher公司),主要工作参数如下:测定模式为KED模式;RF功率1150 W;等离子气流量15.0 L/min;辅助气流量1.0 L/min;雾化气流量1.0 L/min;进样泵流速为30 r/min;进样冲洗时间20 s;扫面方式为跳峰;单元素积分时间为1 s。

    过氧化钠、三乙醇胺、柠檬酸为分析纯,三乙醇胺、柠檬酸作为络合剂使用。

    柠檬酸溶液:浓度为0.8%,溶剂为水。

    732型阳离子交换树脂:在交联为7%的苯乙烯-二乙烯共聚体上带磺酸基(—SO3H)的阳离子交换树脂。

    铑(GSB04-1746-2004)、铼(GSB04-1745-2004)、硼(GSB04-1716-2004)、磷(GSB04-1741-2004)单元素标准储备溶液:浓度为1000 μg/mL,碘(GSB05-1137-1999)单元素标准溶液:浓度为100 μg/g。以上单元素标准储备溶液均由国家有色金属及电子材料分析测试中心定值,逐级稀释后配制成实验用内标液,铼、铑浓度为0.5 μg/mL,硼、磷、碘浓度为1.0 μg/mL。

    实验用水为超纯水(电阻率18.0 MΩ·cm)。

    实验样品为铜铅锌矿石标准物质,与实际样品具有相近的基体组成和主量元素含量。包括:GBW07170为西藏自治区地质矿产勘查开发局中心实验室研制的铜、铅矿石成分分析标准物质;GBW07164和GBW07167为中国地质科学院地球物理地球化学勘查研究所研制的富铜(银)矿石和铅精矿成分分析标准物质;BY0110-1为云南锡业公司研制的锌精矿成分分析标准物质,矿物类型为氧化矿;GBW07234和GBW07235为湖北地质实验研究所研制的铜矿石和铅矿石成分分析标准物质。

    称取待测矿样0.4000 g于刚玉坩埚中,用塑料勺加入2.0 g过氧化钠,坩埚置于预热至500℃的耐火板上放置5 min,再转移到升温至500℃的马弗炉中,升温至750℃,保温10 min,取出后冷却至约100℃,坩埚放入100 mL聚四氟乙烯烧杯中,加入80 mL热水(约80℃)提取,加入2 mL三乙醇胺,加入0.5 μg/mL铼内标溶液5.00 mL,搅拌均匀,取出坩埚,冷却后定容于100 mL容量瓶中,得待测液。

    搅拌过程中移取10.0 mL待测液于50 mL聚四氟乙烯坩埚中,加入0.8%柠檬酸溶液8 mL,摇匀,再加入8~9 g阳离子树脂,摇匀后于回旋振荡器上以振速150~160 r/min振荡15 min,充分离子交换,加入8 mL水,继续于振荡器上振荡20 min后,定容于50 mL容量瓶中,得测定液。

    在100 mL容量瓶中加入逐级稀释后的钨、钼、锡、锗、硒、碲标准溶液,加入2.0 g过氧化钠、内标溶液5.00 mL(内标元素浓度Re:0.5 μg/mL;B:1.0 μg/mL)和2 mL三乙醇胺,定容,摇匀,配制成钨、钼、锡、锗、硒、碲的混合标准曲线溶液,随同样品待测液(1.3.2节)制备成工作曲线溶液。各元素浓度见表 1

    表  1  钨钼锡锗硒碲标准工作溶液
    Table  1.  Standard working solution of tungsten, molybdenum, tin, germanium, selenium and tellurium
    混合标准溶液系列 浓度(ng/mL)
    W Mo Sn Ge Se Te
    S0 0.0 0.0 0.0 0.0 0.0 0.0
    S1 4.0 10.0 4.0 2.0 2.0 1.0
    S2 8.0 20.0 8.0 4.0 4.0 2.0
    S3 20.0 50.0 20.0 10.0 10.0 5.0
    S4 40.0 100.0 40.0 20.0 20.0 10.0
    S5 80.0 200.0 80.0 40.0 40.0 20.0
    S6 120.0 400.0 120.0 60.0 60.0 30.0
    S7 200.0 1000.0 200.0 100.0 100.0 50.0
    下载: 导出CSV 
    | 显示表格

    多元素系统分析中,对熔矿方式的选择要优先考察矿物晶格稳定的难熔元素的熔矿完全程度。6种待测元素中钨、钼、锗[7]、硒、碲[8]可采用高氯酸(硫酸)-硝酸-氢氟酸-(盐酸)以敞开酸溶的方式进行样品分解,样品分解效果好,但采用敞开酸溶法进行锡矿石元素分析时存在矿物分解不完全的风险,且方法适用矿种范围窄[9]。高压封闭酸溶的方式使锡消解完全,但需增压和延长样品消解时间[10],造成溶矿效率低且无法大批量处理样品。

    对于含锡石的难溶铅锌矿石,采用过氧化钠熔融可以使样品分解完全。但碱性熔剂引入了大量盐类物质和基体组分,并含有一定量的金属、非金属杂质,造成分析空白偏高。本法通过将熔剂过筛(10目)、混匀、固定熔剂加入量的方式使空白值保持一致。

    经过氧化钠熔融,样品溶液体系中的总固体溶解量(TDS)较高(大于0.5%),并通过进样系统沉积于采样锥、截取锥和离子透镜,影响ICP-MS测试的稳定性[11]。其中高含量的钠盐将吸收等离子体电离能,降低中心通道的温度,对待测元素产生电离抑制。

    在测定液中加入的柠檬酸,通过N或O电负性较强的阴离子作用于钨、钼、锡金属阳离子中心形成稳定的复合物;锗、硒和碲在强碱性溶液中分别以锗酸根(GeO32-)、硒酸根(SeO42-)、碲酸根(H4TeO62-)的形式存在。强酸型阳离子树脂中的H+在溶液中与Na+发生交换,降低了盐类浓度[12],使溶液由强碱性逐渐转化为弱酸性,离子交换后的溶液pH=4~5;同时使造岩元素铁、铝、钙、镁以及基体元素从溶液中分离,减少了基体干扰。三乙醇胺、柠檬酸作为络合剂,有助于铁、铝元素的交换,使溶液澄清。

    选取标准物质GBW07170、GBW07167和BY0110-1,考察主量元素铜、铅、锌、铁的去除情况,表 2中的数据表明,按照本实验方法处理各主量元素的去除率均高于96%,这些主量元素在测定介质中的实际浓度为0.192 ng/mL~1.28 μg/mL,对待测元素的干扰可基本忽略。

    表  2  主量元素去除试验
    Table  2.  Removal tests of the principal components
    标准物质编号 Cu Pb Zn Fe
    认定值(%) 实测含量(%) 去除率(%) 认定值(%) 实测含量(%) 去除率(%) 认定值(%) 实测含量(%) 去除率(%) 认定值(%) 实测含量(%) 去除率(%)
    GBW07170 12.59 1.28×10-3 99.99 2.24 8×10-5 99.99 1.21 8×10-5 99.99 - 8×10-3 -
    GBW07167 0.028 9.6×10-4 96.57 57.1 8×10-2 99.86 3.3 1.84×10-3 99.94 12 0.16 98.67
    BY0110-1 0.135 2.4×10-5 99.98 0.35 3.44×10-3 99.02 42.98 8.24×10-4 99.99 - 7.2×10-3 -
    注:“-”表示该元素无定值或其去除率无法计算。
    下载: 导出CSV 
    | 显示表格

    选择铼、铑及离子行为与待测元素相近的硼、磷、碘元素(在碱性溶液中以阴离子形式存在)进行内标试验。这些内标元素与待测元素钨、钼、锡、锗、硒、碲的第一电离电位范围为7.460~10.486 eV与7.099~9.752 eV。按照金属和非金属元素进行分组内标试验,分次考察不同仪器条件和不同时间下钨、钼、锡、锗、硒、碲与内标元素的计数值之比,计算各元素测定值的相对标准偏差(RSD,n≥20),试验结果如表 3

    表  3  内标元素选择试验
    Table  3.  Selection tests of internal standards
    内标元素 对应待测元素 RSD(%) 各类样品中内标元素含量范围
    Re W、Mo、Sn、Ge 0.92~2.20 铅锌矿石:0.24~3.5 μg/g
    土壤样品:0.074~0.53 ng/g
    Rh W、Mo、Sn、Ge 1.03~3.55 贵金属矿石:0.017~22 ng/g
    B Se、Te 1.66~2.43 土壤样品:4.6~155 μg/g
    P Se、Te 3.68~4.94 土壤样品:140~1490 μg/g
    I Se、Te 3.93~5.81 土壤样品:0.3~2.9 μg/g
    注:各元素大致含量范围参考国家一级标准物质定值。
    下载: 导出CSV 
    | 显示表格

    在各类地质样品中,铼、铑、碘元素的含量普遍低于10 μg/g,而磷的自然丰度均高于100 μg/g。铼与钨钼锡锗、硼与硒碲的多次测定的相对标准偏差均低于2.5%,测试相关性优于铑、磷和碘内标元素。同时考虑到碘的氢化物可能对碲产生质谱干扰,本实验最终以铼和硼分别作为金属和非金属元素的内标元素。

    质谱常见干扰包括同量异位素的干扰和多原子离子复合物(氢、氧、氩复合物等)的干扰[13]。在本方法中,同量异位素干扰如74Se对74Ge的干扰、氩气中的杂质82Kr对82Se的测定干扰;而多原子离子复合物的干扰包括182W受1H181Ta的干扰,95Mo受40Ar55Mn的干扰,118Sn可能受到16O102Ru和12C106Pd的干扰,铁氧化物58Fe16O和镍氧化物58Ni16O干扰74Ge的测定,66Zn16O干扰82Se的测定,128Te可能受到1H127I的干扰。

    对同量异位素的干扰在线校正,选择干扰元素的异质同位素进行定量测定,根据干扰元素同位素的丰度比计算干扰系数,采用数学公式校正的方法,仪器自动对干扰进行扣除,干扰校正方程见表 4。多原子离子复合物的干扰较为复杂,且氩复合物的干扰难以避免,在测定时选择动能歧视(KED)模式[14],同时加入强酸型阳离子树脂交换去除溶液中大部分的稀土元素、Fe3+、Ni2+、Mn2+及高含量Cu2+、Pb2+、Zn2+等离子,干扰基本可以消除。

    表  4  同位素、相关系数、质谱干扰扣除及方法检出限
    Table  4.  Isotope, correlation coefficient, mass spectrum interference deduction and detection limits
    元素 同位素 相关系数 干扰校正 方法检出限(μg/g)
    树脂处理前 树脂处理后
    W 182W 0.9981 0.9995 - 0.50
    Mo 95Mo 0.9990 0.9999 - 0.15
    Sn 118Sn 0.9954 0.9994 - 0.29
    Ge 74Ge 0.9992 0.9997 -0.0407×78Se 0.15
    Se 82Se 0.9989 0.9995 -1.0010×83Kr 0.05
    Te 128Te 0.9923 0.9995 - 0.03
    注:“-”表示元素无干扰或存在的干扰极小,可忽略。
    下载: 导出CSV 
    | 显示表格

    制备工作曲线溶液时进行基体匹配,因此溶液介质中存在较高浓度的钠盐。本法通过阳离子树脂处理工作曲线溶液,所得工作曲线的相关性优于不加阳离子树脂处理的方法,与同类酸溶研究相比,硒、碲工作曲线的相关性较优[8]。由于加入大量碱性熔剂进行样品熔融,受试剂空白影响,钨、钼、锡元素的检出限高于混合酸酸溶的前处理方法[5],碲的检出限优于国家标准方法和萃取分离-石墨炉原子吸收光谱法检出限0.20 μg/g和0.055 μg/g[4],曲线相关系数及方法检出限见表 4。考虑实际样品中各元素的含量,本方法满足铅锌矿石中多元素的分析测试要求。

    选取标准物质GBW07234、GBW07164及GBW07235按照1.3节实验方法进行准确度试验,计算相对误差和加标回收率;对样品进行平行分析(n=8),计算相对标准偏差(RSD),分析结果列于表 5。标准物质测定的相对误差范围为-8.33%~7.00%,加标回收率为94.9%~107.5%,多次测定相对标准偏差(RSD)均小于8%,方法准确度满足地质矿产实验室测试质量管理规范(DZ/T 0130—2006)的要求(按照样品中各元素含量计算可允许最小相对偏差为16.98%)。与混合酸酸溶的方法相比,钨、钼和锡的相对标准偏差(RSD)略高于ICP-MS法(钨、钼和锡分别为2.9%~3.6%、2.4%~2.9%和2.7%~3.9%)[5],其中钼和锗的相对标准偏差(RSD)略低于孟时贤等测定铅锌矿采用的电感耦合等离子体发射光谱法1.5%~5.4%和1.4%~5.7%[15]

    表  5  准确度和精密度试验
    Table  5.  Accuracy and precision tests of the method
    标准物质编号 元素 参考值(μg/g) 测定值(μg/g) 相对误差(%) 加标量(μg/g) 测定值(μg/g) 回收率(%) RSD(%)
    GBW07234 W 3.9 3.88 -0.51 5.0 8.69 95.8 4.7
    Mo 2.4 2.32 -3.33 2.0 4.51 105.5 2.2
    Sn 3.8 4.05 6.58 5.0 8.93 102.6 3.5
    Ge 0.93 0.94 1.08 1.0 1.91 98.0 2.7
    Se 0.89 0.86 -3.37 1.0 1.84 95.0 6.1
    Te 0.13 0.12 -7.69 0.2 0.34 105.0 7.6
    GBW07164 W 56 54.5 -2.68 50.0 105.5 99.5 2.2
    Mo 137 137.6 0.44 150.0 282.3 98.3 1.5
    Sn 9.7 9.2 -5.15 10.0 18.7 94.9 4.6
    Ge 3.3 3.1 -6.06 5.0 8.90 107.2 2.6
    Se 24 25.1 4.58 30.0 55.3 102.4 1.8
    Te 1.8 1.65 -8.33 2.0 3.71 95.0 5.7
    GBW07235 W 17.6 18.35 4.26 20.0 38.22 103.1 3.2
    Mo 1.6 1.65 3.12 2.0 3.63 101.5 4.8
    Sn 3.0 3.21 7.00 5.0 7.97 99.4 5.6
    Ge 0.90 0.88 -2.22 1.0 1.91 101.0 3.1
    Se 1.7 1.66 -2.35 2.0 3.85 107.5 5.3
    Te 3.9 4.09 4.87 5.0 8.88 99.6 2.2
    下载: 导出CSV 
    | 显示表格

    采用铅锌矿石国家标准方法和传统分析方法,无法同时测定钨、钼、锡、锗、硒、碲,其中低含量元素需要分离富集,分析效率低、流程长且存在不可避免的主量元素干扰。本方法采用过氧化钠碱熔体系,在样品前处理环节通过阳离子树脂交换分离高含量钠盐和可能产生干扰的高含量铅,实现了在一个溶液体系中快速、准确、同时测定多种元素。本研究在降低方法检出限等方面可加强探索以扩大方法适用范围。本方法应用树脂分离富集技术去除干扰,优化了测定介质,为低含量难熔元素的准确测定提供了思路,同时可考虑应用于地质样品中硼、碘等元素的分析测试。

  • 图  1   碰撞气流速对78Se信号强度的影响

    Figure  1.   Effect of gas flow velocity on signal intensity of 78Se

    表  1   不同消解时间下硒含量测定结果

    Table  1   Analytical results of Se in different digestion time

    土壤标准
    物质编号
    Se认定值
    (μg/g)
    不同消解时间Se测定值(μg/g)
    0.5h 1.0h 1.5h 2.0h 2.5h 3.0h
    GBW07303 1.0±0.2 0.74 0.86 0.92 0.96 0.95 0.98
    GBW07405 1.6±0.2 0.88 1.49 1.58 1.61 1.63 1.59
    下载: 导出CSV

    表  2   土壤标准物质中硒的测定结果

    Table  2   Analytical results of Se in soil standard materials


    土壤标准
    物质编号
    Se认定值
    (μg/g)
    12次Se测定值
    (μg/g)
    测定平均值
    (μg/g)
    相对误差
    (%)
    RSD
    (%)
    1.02 0.94 0.91 1.01
    GBW07303 1.0±0.2 1.03 1.01 0.96 0.95 0.98 -1.67 3.76
    1.00 1.01 0.97 0.99
    0.26 0.32 0.28 0.28
    GBW07304 0.29±0.08 0.26 0.29 0.27 0.28 0.28 -2.01 6.09
    0.30 0.28 0.29 0.30
    0.16 0.18 0.15 0.15
    GBW07309 0.16±0.03 0.17 0.18 0.16 0.17 0.16 2.08 6.57
    0.17 0.16 0.15 0.16
    0.095 0.094 0.088 0.086
    GBW07403 0.09±0.02 0.082 0.10 0.096 0.093 0.093 2.96 5.64
    0.091 0.093 0.099 0.095
    0.64 0.71 0.66 0.61
    GBW07404 0.64±0.14 0.68 0.68 0.69 0.66 0.66 2.99 4.41
    0.62 0.65 0.64 0.67
    1.63 1.61 1.55 1.66
    GBW07405 1.6±0.2 1.71 1.57 1.62 1.61 1.63 1.72 2.86
    1.64 1.69 1.65 1.59
    下载: 导出CSV

    表  3   实际样品中硒的检测结果与方法比对结果

    Table  3   Analytical results of Se in real samples and comparison of different methods

    样品编号 Se测定值(μg/g)
    本方法 HJ 680—2013方法
    SY-1 0.34 0.36
    SY-2 0.13 0.12
    SY-3 0.63 0.61
    SY-4 0.48 0.49
    SY-5 1.03 1.05
    SY-6 0.41 0.39
    SY-7 0.25 0.26
    SY-8 0.17 0.16
    SY-9 0.52 0.49
    SY-10 0.51 0.51
    SY-11 0.84 0.88
    SY-12 0.69 0.72
    SY-13 0.23 0.21
    SY-14 0.14 0.14
    SY-15 1.83 1.85
    SY-16 0.74 0.71
    SY-17 0.096 0.10
    SY-18 1.85 1.83
    SY-19 0.32 0.30
    SY-20 0.21 0.20
    下载: 导出CSV
  • 《岩石矿物分析》编委会.岩石矿物分析(第四版第三分册)[M].北京:地质出版社, 2011.

    The editorial committee of <Rock and mineral analysis>. Rock and mineral analysis (The fourth edition:Vol.Ⅲ)[M].Beijing:Geological Publishing House, 2011.

    刘金巍, 刘雪松, 边超, 等.甲烷动态反应电感耦合等离子体质谱法测定地下水中痕量硒[J].岩矿测试, 2019, 38(1):85-91. doi: 10.15898/j.cnki.11-2131/td.201804200049

    Liu J W, Liu X S, Bian C, et al.Determination of trace selenium in groundwater by DRC ICP-MS[J].Rock and Mineral Analysis, 2019, 38(1):85-91. doi: 10.15898/j.cnki.11-2131/td.201804200049

    王俊伟, 钱蜀, 李海霞, 等.电感耦合等离子体质谱法测定土壤样品中的痕量硒元素[J].中国环境监测, 2012, 28(3):97-100. doi: 10.15898/j.cnki.11-2131/td.202003050025

    Wang J W, Qian S, Li H X, et al.Determination of trace selenium in soils by inductively coupled plasma-mass spectrometry[J].Environmental Monitoring in China, 2012, 28(3):97-100. doi: 10.15898/j.cnki.11-2131/td.202003050025

    钱薇, 唐昊冶, 王如海, 等.一次消解土壤样品测定汞、砷和硒[J].分析化学, 2017, 45(8):1215-1221. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxhx201708020

    Qian W, Tang H Y, Wang R H, et al.Determination of mercury, arsenic and selenium in soils by one-time digestion[J].Chinese Journal of Analytical Chemistry, 2017, 45(8):1215-1221. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxhx201708020

    谭芳维, 黄菲, 唐秀龙, 等.水浴消解-原子荧光法测定土壤中硒、锑的研究[J].广州化工, 2019, 47(6):103-105. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gzhg201906043

    Tan F W, Huang F, Tang X L, et al.Determination of selenium and antimony in soil by water bath digestion-atomic fluorescencel[J].Guangzhou Chemical Industry, 2019, 47(6):103-105. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gzhg201906043

    陈海英.王水水浴消解-双道原子荧光光谱法(AFS)同时测定土壤中的汞和硒[J].农业科技与装备, 2013, 10(10):13-15. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=nyjxhydqh201310008

    Chen H Y.Simultaneous determination of mercury and selenium in soil with aqua regia digestion in water bath and double channel atomic fluorescence spectrometry (AFS)[J].Agricultural Science & Technology and Equipment, 2013, 10(10):13-15. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=nyjxhydqh201310008

    林海兰, 朱日龙, 于磊, 等.水浴消解-原子荧光光谱法测定土壤和沉积物中砷、汞、硒、锑和铋[J].光谱学与光谱分析, 2020, 40(5):1528-1533. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gpxygpfx202005037

    Lin H L, Zhu R L, Yu L, et al.Determination of arsenic, mercury, selenium, antimony and bismuth in soil and sediments by water bath digestion-atomic fluorescence spectrometry[J].Spectroscopy and Spectral Analysis, 2020, 40(5):1528-1533. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gpxygpfx202005037

    黄薇, 符式锦, 王旭日, 等.微波消解-ICP-MS测定土壤及植物中硒的含量[J].广州化工, 2014, 42(23):146-148. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=zgmengy201704053

    Huang W, Fu S J, Wang X R, et al.Determination of selenium in soil and plant by microwave digestion-ICP-MS[J].Guangzhou Chemical Industry, 2014, 42(23):146-148. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=zgmengy201704053

    刘芸, 曹国松, 程佩, 等.微波消解-ICP-MS法测定土壤中的硒含量[J].化学与生物工程, 2017, 34(11):67-70. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hbhg201711017

    Liu Y, Cao G S, Cheng P, et al.Determination of selenium content in soil by microwave digestion-ICP-MS[J].Chemistry & Bioengineering, 2017, 34(11):67-70. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hbhg201711017

    田敏, 刘畅.两种消解土壤中硒的方法对比分析[J].黑龙江环境通报, 2007, 31(3):33-34. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hljhjtb200703015

    Tian M, Liu C.Comparative analysis of two digestion method of selenium in soil[J].Heilongjiang Environmental Journal, 2007, 31(3):33-34. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hljhjtb200703015

    屈明华, 陈雄弟, 倪张林, 等.DRC-ICP-MS法测定土壤硒前处理方法研究[J].土壤通报, 2019, 50(3):698-703. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=trtb201903027

    Qu M H, Chen X D, Ni Z L, et al.Pretreatment for determination of soil selenium by ICP-MS with dynamic reaction cell[J].Chinese Journal of Soil Science, 2019, 50(3):698-703. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=trtb201903027

    严进.双氧水氧化1-(2-吡啶偶氮)-2-萘酚动力学光度法测定痕量硒[J].广州化工, 2016, 44(21):132-134. http://www.cqvip.com/QK/93773X/201621/670498070.html

    Yan J.Determination of selenium by catalytic kinetic spectrophotometry in hydrogen peroxide-PAN system[J].Guangzhou Chemical Industry, 2016, 44(21):132-134. http://www.cqvip.com/QK/93773X/201621/670498070.html

    韩亚, 郭伟, 汪洪.电感耦合等离子体质谱(ICP-MS)法与氢化物发生-原子吸收光谱(HG-AAS)法测定土壤中硒含量的对比研究[J].中国无机分析化学, 2020, 10(3):28-32. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=zgwjfxhxwz202003006

    Han Y, Guo W, Wang H.Method comparison for determination of selenium in soil by ICP-MS and HG-AAS[J].Chinese Journal of Inorganic Analytical Chemistry, 2020, 10(3):28-32. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=zgwjfxhxwz202003006

    冯永明, 邢应香, 刘洪青, 等.微波消解-电感耦合等离子体质谱法测定生物样品中微量硒的方法研究[J].岩矿测试, 2014, 33(1):34-39. http://www.ykcs.ac.cn/article/id/00a7dfe7-2a17-45e5-ada2-503f476cc501

    Feng Y M, Xing Y X, Liu H Q, et al.Determination of trace selenium in biological samples by inductively coupled plasma-mass spectrometry with microwave digestion[J]. Rock and Mineral Analysis, 2014, 33(1):34-39. http://www.ykcs.ac.cn/article/id/00a7dfe7-2a17-45e5-ada2-503f476cc501

    程秀花, 王海蓉, 黎卫亮, 等.电感耦合等离子体质谱法测定硒时多元素干扰的碰撞/反应研究及其在地质样品中的应用[J].冶金分析, 2015, 35(12):5-9. http://www.cnki.com.cn/Article/CJFDTotal-YJFX201512002.htm

    Cheng X H, Wang H R, Li W L, et al.Study on collision/reaction for multielement interference in determination of selenium by inductively coupled plasma mass spectrometry and its application to geological sample[J].Metallurgical Analysis, 2015, 35(12):5-9. http://www.cnki.com.cn/Article/CJFDTotal-YJFX201512002.htm

    徐鹏, 孙亚莉.Carius管密封溶样-等离子体质谱法测定环境样品中镓、锗、砷、硒、镉、锡、锑、碲、汞、铅和铋[J].分析化学, 2010, 38(4):581-584. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxhx201004027

    Xu P, Sun Y L.Determination of Ga, Ge, As, Se, Cd, Sn, Sb, Te, Hg, Pb and Bi in environmental samples by inductively coupled plasma mass spectrometry combined with Carius tube digestion[J].Chinese Journal of Analytical Chemistry, 2010, 38(4):581-584. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxhx201004027

    D'Ilio S, Violante N, Majorani C, et al.Dynamic reaction cell ICP-MS for determination of total As, Cr, Se and Ⅴ in complex matrices:Still a challenge?A review[J].Analytica Chimica Acta, 2011, 698(1):6-13. http://test.europepmc.org/abstract/MED/21645653

    陈波, 刘洪青, 邢应香.电感耦合等离子体质谱法同时测定地质样品中锗硒碲[J].岩矿测试, 2014, 33(2):192-196. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=ykcs201402006

    Chen B, Liu H Q, Xing Y X.Simultaneous determination of Ge, Se and Te in geological samples by inductively coupled plasma-mass spectrometry[J].Rock and Mineral Analysis, 2014, 33(2):192-196. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=ykcs201402006

    刘征宙, 曹丽丽, 陈浩云, 等.电感耦合等离子体质谱法-碰撞反应池技术测定高纯度磷酸二氢钾中痕量金属元素[J].化学试剂, 2015, 37(9):809-811, 842. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=huaxsj201509009

    Liu Z Z, Cao L L, Chen H Y, et al.Detection of trace metal elements in potassium dihydrophate with ICP-MS(CCT) method[J].Chemical Reagents, 2015, 37(9):809-811, 842. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=huaxsj201509009

    余兴.电感耦合等离子体四极杆质谱碰撞/反应池技术现状与进展[J].冶金分析, 2013, 33(3):14-23. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yjfx201303003

    Yu X.The present situation and advance in collision/reaction cell technique of inductively coupled plasma quadrupole mass spectrometry[J].Metallurgical Analysis, 2013, 33(3):14-23. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yjfx201303003

    章连香, 冯先进.八极杆碰撞/反应池(ORS) -电感耦合等离子体质谱(ICP-MS)法测定复杂矿物中的稀土元素[J].中国无机分析化学, 2017, 7(2):22-26. http://www.cnki.com.cn/Article/CJFDTotal-GUAN200506039.htm

    Zhang L X, Feng X J.Determination of rare earth elements in complex minerals by octopole reaction system (ORS)-inductively coupled plasma mass spectrometry (ICP-MS)[J].Chinese Journal of Inorganic Analytical Chemistry, 2017, 7(2):22-26. http://www.cnki.com.cn/Article/CJFDTotal-GUAN200506039.htm

    韩建华, 孙传强, 汪曣, 等.电感耦合等离子体质谱中碰撞反应池的模拟探讨[J].冶金分析, 2014, 34(9):1-7. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yjfx201409001

    Han J H, Sun C Q, Wang Y, et al.Discussion on the simulation of collision reaction cell in inductively coupled plasma mass spectrometry[J].Metallurgical Analysis, 2014, 34(9):1-7. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yjfx201409001

    陕红, 孙宝利, 黄金丽, 等.DRC-ICP-MS测定蜂王浆中硒的方法研究[J].分析测试学报, 2016, 35(9):1191-1194. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxcsxb201609022

    Shan H, Sun B L, Huang J L, et al.Analysis of selenium in royal jelly by ICP-MS with dynamic reaction cell[J].Journal of Instrumental Analysis, 2016, 35(9):1191-1194. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxcsxb201609022

    杏朝刚, 袁京群, 李士敏.微波消解-动态反应池电感耦合等离子体质谱测定农产品中的痕量硒[J].浙江农业学报, 2018, 30(8):1414-1419. http://www.cnki.com.cn/Article/CJFDTotal-ZJNB2018082400J.htm

    Xing C G, Yuan J Q, Li S M.Determination of trace selenium in agricultural products with microwave digestion-dynamic reaction cell inductively coupled plasma mass spectrometry[J].Acta Agriculturae Zhejianggensis, 2018, 30(8):1414-1419. http://www.cnki.com.cn/Article/CJFDTotal-ZJNB2018082400J.htm

    徐进力, 邢夏, 唐瑞玲, 等.动能歧视模式ICP-MS测定地球化学样品中14种痕量元素[J].岩矿测试, 2019, 38(4):394-402. doi: 10.15898/j.cnki.11-2131/td.201812070131

    Xu J L, Xing X, Tang R L, et al.Determination of 14 trace elements in geochemical samples by ICP-MS using kinetic energy discrimination mode[J].Rock and Mineral Analysis, 2019, 38(4):394-402. doi: 10.15898/j.cnki.11-2131/td.201812070131

    黄子敬, 陈孟君, 邓华阳, 等.微波消解-ICP-MS混合模式测定动植物源食品中11种金属元素[J].分析试验室, 2017, 36(1):24-28. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxsys201701006

    Huang Z J, Chen M J, Deng H Y, et al.Determination of 11 trace elements in animal and plant origin food by microwave digestion with ICP-MS in mixed mode[J].Chinese Journal of Analysis Laboratory, 2017, 36(1):24-28. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=fxsys201701006

    林珍, 黄超冠, 卢燕平, 等.沸水浴-氢化物发生原子荧光光谱法测定土壤中的硒[J].广州化学, 2017, 42(3):34-37. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gzhx201703006

    Lin Z, Huang C G, Lu Y P, et al.Boilingwater bath-determination of selenium in soil by hydride generation atomic fluorescence spectrometry[J].Guangzhou Chemistry, 2017, 42(3):34-37. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gzhx201703006

    郑欣.X Series 2 ICP-MS CCTED在食品样品超痕量元素分析中的应用[J].环境化学, 2009, 28(3):467-468. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hjhx200903036

    Zheng X.Application of X Series 2 ICP-MS CCTED in analysis of ultra-trace elements of food samples[J].Environmental Chemistry, 2009, 28(3):467-468. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=hjhx200903036

  • 期刊类型引用(15)

    1. 苏立城,陈晓珊,罗志忠,胡英,陈煜佳,吴道铭,曾曙才. 氮添加对森林土壤有机碳库固存及CO_2排放的影响研究进展. 生态学报. 2024(07): 2717-2733 . 百度学术
    2. 易志远,罗霄,王玉霞,苏丽,乔成龙,薛斌,杜灵通. 贺兰山东麓典型葡萄园土壤有机碳库组成及其活跃度. 水土保持通报. 2024(03): 390-398 . 百度学术
    3. 李朝英,郑路,郑之卓,李华,王亚南,明安刚. 自动滴定仪测定土壤有机碳及其组分的方法优化. 岩矿测试. 2024(04): 632-640 . 本站查看
    4. 高放,洪煜,孙燕,宓文海,陈硕桐. 秸秆还田对盐碱地土壤有机碳库及其组分影响的研究进展. 华北农学报. 2024(S1): 143-149 . 百度学术
    5. 卢伟伟,胡嘉欣,陈思桦,陈玮铃,冯思宇. 苏北滨海土壤无机碳含量的测定方法比较. 南京林业大学学报(自然科学版). 2023(01): 76-82 . 百度学术
    6. 吴紫琪,何语堂,羊妍珂,陶玉林,吴骏男,蒋振楠,严小军,廖智,刘雪珠,何建瑜. 厚壳贻贝(Mytilus coruscus)养殖区沉积物微生物多样性及固碳潜力研究. 海洋与湖沼. 2023(02): 502-513 . 百度学术
    7. 陈宗定,许春雪,刘贵磊,王岚,孙慧中,安子怡. 元素分析仪和燃烧—红外吸收光谱法测定土壤和沉积物中总碳含量的比对. 理化检验-化学分册. 2023(07): 771-775 . 百度学术
    8. 袁冬梅,严令斌,武亚楠,张丽敏,杨熳,喻理飞. 喀斯特高原区植被恢复过程土壤有机碳的变化. 山地农业生物学报. 2022(02): 20-25 . 百度学术
    9. 张延,高燕,张旸,Gregorich Edward,李秀军,陈学文,张士秀,梁爱珍. Rock-Eval热分解法及其在土壤有机碳研究中的应用. 土壤与作物. 2022(03): 282-289 . 百度学术
    10. 严洁,于小娟,唐明,段文艳,李鑫,郝一鸣,盛敏. 造林对乌海露天煤矿复垦地土壤养分和碳库的影响. 林业科学研究. 2021(04): 66-73 . 百度学术
    11. 王尧,田衎,封跃鹏,王伟. 土壤中总有机碳环境标准样品研制. 岩矿测试. 2021(04): 593-602 . 本站查看
    12. 岑言霸,苏斌,冯泽波,史正涛. 滇池入湖河流pH时空分异特征及其变化机理. 科学技术与工程. 2021(26): 11432-11442 . 百度学术
    13. 安帅,陈鉴惠,赵任远,宋丽华. 东北黑土地中碳赋存形态分析方法研究. 地质与资源. 2021(06): 716-721+709 . 百度学术
    14. 殷陶刚,窦向丽,张旺强,和振云. 应用高频红外碳硫仪测定农用地土壤样品中有机质含量. 岩矿测试. 2020(04): 631-638 . 本站查看
    15. 曹彬彬,朱熠辉,姜禹含,师江澜,田霄鸿. 添加石灰和秸秆对土有机碳固持的影响. 中国农业科学. 2020(20): 4215-4225 . 百度学术

    其他类型引用(13)

图(1)  /  表(3)
计量
  • 文章访问数:  3358
  • HTML全文浏览量:  1079
  • PDF下载量:  102
  • 被引次数: 28
出版历程
  • 收稿日期:  2020-03-04
  • 修回日期:  2020-04-19
  • 录用日期:  2020-06-25
  • 发布日期:  2020-08-31

目录

/

返回文章
返回