MA Xin-rong, MA Sheng-feng, WANG Lei, WEN Hong-li, GONG Ai-hua, XU Jun-yu. Determination of As, Sb, S, Cu, Pb, Zn in Arsenic Ore and Stibium Ore by Inductively Coupled Plasma-Atomic Emission Spectrometry With Aqua Regia Digestion[J]. Rock and Mineral Analysis, 2011, 30(2): 190-194.
Citation: MA Xin-rong, MA Sheng-feng, WANG Lei, WEN Hong-li, GONG Ai-hua, XU Jun-yu. Determination of As, Sb, S, Cu, Pb, Zn in Arsenic Ore and Stibium Ore by Inductively Coupled Plasma-Atomic Emission Spectrometry With Aqua Regia Digestion[J]. Rock and Mineral Analysis, 2011, 30(2): 190-194.

Determination of As, Sb, S, Cu, Pb, Zn in Arsenic Ore and Stibium Ore by Inductively Coupled Plasma-Atomic Emission Spectrometry With Aqua Regia Digestion

More Information
  • Received Date: May 26, 2010
  • Revised Date: November 27, 2010
  • The method for determining concentrations of As, Sb, S, and Cu, Pb, Zn which are above 100 μg/g, within arsenic ore and stibium ore by inductively coupled plasma-atomic emission spectrometry(ICP-AES)with aqua regia digestion is reported in this paper. The experimental conditions such as placement time, solution acidity, and the influence of oxidant and complexing agents on As, Sb, S and the other elements were studied. The relative error (RE) was determined to be between -0.17% and 7.74% with a RSD (n=5) of <2% if the concentrations of As, Sb, S in the samples were in the range of 0.74-39.7%. However, the RE was from -2.5% to 4.79% and RSD(n=5) was <2% if the Sb concentration is lower than 100-500 μg/g. The RE was determined to be between -10.3% and 10.3% with a RSD(n=5) of generally less than 5% if the Cu, Pb and Zn concentrations were more than 100 μg/g. No accurate data were obtained for Cu, Pb and Zn if the concentrations were lower than 100 μg/g, limited by the large dilution factor of 1000. The accuracy and precision of the method were validated by reference materials.
  • 袁玄晖,曾慧芳.等离子体直读光谱法分析单矿物初探[J].中国地质科学院院报,1986(14):125-132.
    常平,王松君,孙春华, 苏维娜,王丽娟.电感耦合等离子体原子发射光谱法测定黄铁矿中微量元素[J].岩矿测试,2002 ,21(4):304-306.
    王松君,常平,王璞珺, 侯天平.电感耦合等离子体发射光谱法直接测定黄铜矿中多元素[J].岩矿测试,2004,23(3):228-230.
    冯宝艳.ICP-AES测定铜精矿中As,Sb,Bi,Ca,Mg,Pb,Co,Zn和Ni[J].分析试验室,2008,27(增刊):67-68.
    曾慧芳,何红蓼,王伟莹,袁玄晖.等离子体光谱法分析黄铁矿的研究[J].岩石矿物及测试,1984,4(4):335-339.
    王松君,常平,王璞珺, 侯天平,侯悦. ICP-AES测定闪锌矿中9种元素的方法[J].吉林大学学报:理学版,2006,44(6):993-996.
    巫涛.基于原子光谱法的锑矿中的砷元素检测[J].化学工程与装备,2008(6):123-124.
    袁爱萍,唐艳霞,黄玉龙,汪静玲,覃然,吴建玲,孟文飞.氢化物-原子荧光法测定锑精矿中痕量砷、汞的研究[J].光谱学与光谱分析,2006,26(8):1553-1556.
    周耀明,余江,于磊,陈一清,罗岳平.ICP-AES测定高砷铁矿中的砷和钒[J].光谱实验室,2007,24(5):829-831.
    曾惠芳.ICP-AES测定辉锑矿中的多元素组份[J].岩矿测试,1990,9(2):17-26.
    曾惠芳.等离子体发射光谱分析毒砂单矿物[J].岩矿测试,1992,11(3):211-216.
    范凡,温宏利,屈文俊,曹亚萍.王水溶样-等离子体质谱法同时测定地质样品中砷锑铋银镉铟[J].岩矿测试,2009,28(4):333-336.

Catalog

    Article views (2290) PDF downloads (1492) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return