• Core Journal of China
  • DOAJ
  • Scopus
  • Chinese Scientific and Technical Papers and Citations (CSTPC)
  • Chinese Science Citation Database (CSCD)
MA Sheng-feng, WEN Hong-li, XU Jun-yu, QU Wen-jun, CAO Ya-ping. Determination of 44 Elements in Groundwater by Inductively Coupled Plasma-Mass Spectrometry[J]. Rock and Mineral Analysis, 2010, 29(5): 552-556.
Citation: MA Sheng-feng, WEN Hong-li, XU Jun-yu, QU Wen-jun, CAO Ya-ping. Determination of 44 Elements in Groundwater by Inductively Coupled Plasma-Mass Spectrometry[J]. Rock and Mineral Analysis, 2010, 29(5): 552-556.

Determination of 44 Elements in Groundwater by Inductively Coupled Plasma-Mass Spectrometry

More Information
  • Received Date: January 17, 2010
  • Revised Date: May 18, 2010
  • 44 kinds of elements in underground water were simultaneously analyzed by inductively coupled plasma-mass spectrometry (ICP-MS), which only took about 2~3 minutes for each sample. The detection limits of the method for the analytes were in the range of 0.002~0.981 μg/L and the recoveries were 90.0%~110.0% with precision of lower than 10% RSD (n=10) for most of the elements, which satisfied the technical standard requirements of quality control for inorganic analysis in underground water quality survey. The method provides the advantages of low detection limits, high precision and accuracy, high efficiency and has been successfully applied to routine analysis of these elements in groundwater samples.
  • 地质调查标准汇编.实验测试方法(第一分册) .
    李春颖.ICP-MS法测定地下水中稀土元素的研究[J].稀土,2007,28(6):78-80.
    铁梅,李闯,费金岩,师晓帆,李华为,臧树良. ICP -MS同时测定饮用水中25种元素的研究[J].环境科学与管理,2007,32(4):135-139.
    辛士刚,王莹.水中多种微量元素的直接测定[J].沈阳师范大学学报:自然科学版,2003,21(2):136-138.
    吴梅贤,李献华,刘颖,涂湘林.电感耦合等离子体质谱法测定水中痕量元素[J].理化检验:化学分册,2007,43(5):391-393.
    徐先顺,张新荣,彭玉秀.电感耦合等离子体质谱在水质分析中的应用[J].中国卫生检验杂志,2006,16(6):763-766.
    李韬,朱艳.ICP/MS法对实验室用水的分析[J].环境监测管理与技术,2002,14(1):32-33.
    朱晨红.ICP-MS测定饮用水中的痕量元素[J].上海计量测试,2004(2):53-54.
    吕杰.ICP-AES法同时测定饮用水中Pb,As等11种金属元素[J].光谱学与光谱分析,2003,23(4):779 -784.
    刘莉.环境监测水质分析中加标回收实验回收率计算的研究[J].安徽冶金科技职业学院学报,2005,15(2):73-75.
    刘玺祥,李东雷,梁楠,舒红,王英杰.电感耦合等离子体质谱法测定饮用水中微量元素[J].吉林地质,2004,23(2):55-57.
    刘丽萍,张妮娜,张岚,张勐.电感耦合等离子体质谱法测定矿泉水中23种元素[J].质谱学报,2005,26(1):27-31.
    刘桂华,谢建滨.电感耦合等离子体光谱和质谱法用于饮水中多元素分析的研究[J].卫生研究,2000,29(6):359-361.
    闵广全,邵文军,王瑞敏,徐艳秋.电感耦合等离子体质谱法(ICP-MS)同时测定水中多种元素[J].检测与分析,2006,9(8):31-33.
    任成忠,毛丽芬.加标回收实验的实施及回收率计算的研究[J].工业安全与环保,2006, 32(2):9-11.

Catalog

    Article views (2251) PDF downloads (1623) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return