Detection of Carcinogenic Aromatic Amines in Textiles by Desorption Electrospray Ionization Mass Spetrometry
-
ABSTRACT
Using a mixture of methanol/water/acetic acid (volume ratio 49∶49∶2) as the electrospray liquid and under the optimized experimental condition, 24 kinds of carcinogenic aromatic amines in various texture of textile samples were directly and nondestructively detected by desorption electrospray ionization mass spectrometry(DESI-MS) with satisfactory results. The mean analysis time for a single analyte in a sample was about 30 s, more efficient due to without sample pretreatment. Furthermore, in virtue of the special performances of tandemMS, the false positive results could be effectively eliminated. The method provides the advantages of high sensitivity (typical detection limit of 10-9 g/kg rang for most aromatic amines), high precision (5%~10%RSD, n=10) and more efficiency. The method has been applied to the direct and nondestructive determination of carcinogenic aromatic amines in various textures of textile samples.
-
-