地下水中有机氯农药测量方法准确度的平衡均匀水平试验
A Balanced Uniform-Level Experiment for the Accuracy of Organochlorine Pesticides Measurement Method in Groundwater
-
摘要: 采用5个浓度水平样品通过7家实验室进行协同评定试验,验证了地下水中六氯苯、α-HCH、β-HCH、γ-HCH、δ-HCH、p,p'-DDE、p,p'-DDD、o,p'-DDT、p,p'-DDT有机氯农药分析方法的稳定性与准确性。测量结果经一致性和离群值检验表明,地下水中9种有机氯农药组分在3.00~56.5 ng/L浓度水平范围内,重复性标准差为0.50~0.77 ng/L,再现性标准差为1.92~3.03 ng/L,单个样品中的2,4,5,6-四氯间二甲苯和二丁基氯菌酸酯替代物质量监控指标回收率分别为58.8%~99.5%和79.2%~117%。检测方法准确、可靠。Abstract: The stability and accuracy of the measurement method for hexachlorobenzene, α-HCH, β-HCH, γ-HCH, δ-HCH, p,p'-DDE, p,p'-DDD, o,p'-DDT and p,p'-DDT in groundwater has been determined by a balanced uniform-level experiment for 5 different content level samples from 7 laboratories. After being verified for consistency and outliers, the statistical results of 9 organochlorine pesticides in groundwater indicated that the repeatability standard deviation was 0.50-0.77 ng/L and the reproducibility standard deviation was 1.92-3.03 ng/L within a level range of 3.00-56.5 ng/L. The recovery rates of surrogates for 2,4,5,6-tetrachloro-m-xylene and dibutyl chlorendate were 58.8%-99.5% and 79.2%-117%, respectively. The detection method was accurate and reliable.
-
Keywords:
- groundwater /
- organochlorine /
- pesticides /
- inter-laboratory /
- validation
-
-
牛军峰,余刚,刘希涛.水相中POPs光化学降解研究进展[J].化学进展,2005,17(5):938-948. Ulberth F. Certified reference materials for inorganic and organic contaminants in environmental matrices[J]. Analytical and Bioanalytical Chemistry, 2006, 386(4): 1121-1136. Ulberth F. Certified reference materials for inorganic and organic contaminants in environmental matrices[J]. Analytical and Bioanalytical Chemistry, 2006, 386(4): 1121-1136.
Zhao G F, Xu Y, Han G G, Ling B. Biotransfer of persistent organic pollutants from a large site in China used for the disassembly of electronic and electrical waste[J]. Environmental Geochemistry and Health, 2006,28(4): 341-351. Zhao G F, Xu Y, Han G G, Ling B. Biotransfer of persistent organic pollutants from a large site in China used for the disassembly of electronic and electrical waste[J]. Environmental Geochemistry and Health, 2006,28(4): 341-351.
李松,饶竹,宋淑玲.全国地下水调查中12种半挥发性必检组分的测定[J].岩矿测试, 2008,27(2):91-94. 李松,饶竹.气相色谱法测定地下水中HCH结果的不确定度评定[J].岩矿测试, 2008,27(4): 295-298. 中国地质调查局.地下水污染调查评价规范 (1:50000-1:250000)[S].2006. 李松,饶竹,黄毅,贾静.正态分布检验在地下水检测质量控制中的应用[J].岩矿测试,2010,29(5): 585-589. ISO 5725-1: 1994, Accuracy (trueness and precision) of measurement methods and results—Part 1: General principles and definitions [S]. ISO 5725-1: 1994, Accuracy (trueness and precision) of measurement methods and results—Part 1: General principles and definitions [S].
ISO 5725-2: 1994, Accuracy (trueness and precision) of measurement methods and results—Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method [S]. ISO 5725-2: 1994, Accuracy (trueness and precision) of measurement methods and results—Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method [S].
Hough T, Edwards K. The reproducibility of videoker-atoscope measurements as applied to the human cornea[J]. Contact Lens and Anterior Eye,1999, 22(3): 91-99. Hough T, Edwards K. The reproducibility of videoker-atoscope measurements as applied to the human cornea[J]. Contact Lens and Anterior Eye,1999, 22(3): 91-99.
Heyden Y, Smeyers-Verbeke J. Set-up and evaluation of interlaboratory studies[J].Journal of Chromatography A,2007,1158: 158-167. Heyden Y, Smeyers-Verbeke J. Set-up and evaluation of interlaboratory studies[J].Journal of Chromatography A,2007,1158: 158-167.
郑用熙.分析化学中的数理统计方法[M].北京: 科学出版社,1991: 1-19. 李松,饶竹.地下水中12项半挥发性有机污染物测定的质量控制[J].岩矿测试, 2009,28(2): 157-160. 李权龙,袁东星,陈猛.替代物和内标物在环境样品分析中的作用及应用[J].海洋环境科学,2002,21(4): 46-49. 韩永志.标准物质手册[M].北京: 中国计量出版社,1998: 623-624. 韩永志.统计学在理化检验中的应用 第六讲 正态分布及其检验(续)[J].理化检验:化学分册,2000,36(3): 138-141.
计量
- 文章访问数: 1443
- HTML全文浏览量: 13
- PDF下载量: 960