石墨炉原子吸收光谱法测定地球化学样品中微量铬
Determination of Trace Chromium in Geochemical Samples by Graphite Furnace Atomic Absorption Spectrometry
-
摘要: 应用ZEEnit 600型石墨炉原子吸收分光光度计测定地球化学样品中微量铬。在分解样品过程中,加入高氯酸,使Cr(Ⅱ)、Cr(Ⅲ)同时被氧化为Cr(Ⅵ),避免了Cr(Ⅲ)和Cr(Ⅵ)的吸光度不同而造成的分析误差。采用最大功率升温和纵向加热石墨管技术,测定铬的原子化温度降低至2100℃,以抗坏血酸作基体改进剂,测定灵敏度得到提高,改善了方法精密度,并且延长了石墨管的使用寿命。采用交流塞曼扣背景测量技术,方法的线性范围为0~200 ng/mL,相关系数为0.9980;铬的检出限降低至0.05 μg/g(稀释因子为2500),方法精密度(RSD)为2.11%~5.96%。经国家一级地球化学标准物质验证,测定值与标准值吻合,结果准确可靠。
-
关键词:
- 铬 /
- 地球化学样品 /
- 石墨炉原子吸收光谱法
Abstract: This article described the application of the ZEEnit 600 graphite furnace atomic absorption spectrophotometer on determination of trace chromium in geochemical samples. The HClO4 was added during digestion to oxidize both Cr(Ⅱ) and Cr(Ⅲ) to Cr(Ⅳ), which avoid the analysis error caused by the different absorbencies of Cr(Ⅱ) and Cr(Ⅲ). The atomization temperature of Cr was reduced to 2100℃ by the technique of longitudinal heating at maximum speed in graphite furnace. The addition of ascorbic acid as matrix modifier improved the sensitivity and precision of the measurement, meanwhile increased the service life of graphite furnace. The linear range is from 0 to 200 ng/mL and the correlation coefficient is 0.9980 with background correction by using inverse Zeeman effect. The detection limits of the method is 0.05 μg/g (dilution factor is 2500), the precision of the method (RSD) is 2.11%-5.96%. The method has been validated by the national standard materials. The measured results were consistent with the certified values, and the results were accurate and reliable.-
Keywords:
- chromium /
- geochemical /
- samples /
- graphite /
- furnace
-
-
冯素玲,唐安娜,樊静.荧光分析法测定痕量铬[J].分析化学,2001,29(5):558-560. 黄淦全,钱沙华,钟山.离子浮选石墨炉原子吸收光谱法测定水中痕量Cr(Ⅵ)、Cr(Ⅲ)[J].分析科学学报,1995,11(4):32-35. 迟锡增,林梅,时彦.石墨炉原子吸收光谱法直接测定痕量Cr及其价态[J].北京师范大学学报:自然科学版,1991,27(4):461-464. 池泉,史建波,梅俊.石墨炉原子吸收光谱法测定土壤中可交换态Cr(Ⅲ)和Cr(Ⅵ) [J].分析试验室,2002,21(2):63-66. 何金兰.用原子吸收光谱对痕量铬作价态分析[J].分析化学,1995,23(9):1047-1050. 李占双,李茹民.石墨炉原子吸收光谱法测定废水中的铬(Ⅵ)与铬(Ⅲ) [J].应用科技,2001,28(3):39-42. 朱珣丽,朱世文,李淑清,孙好芬.铬的不同价态对火焰原子吸收法测定的影响[J].青岛建筑工程学院学报,2001,21(3):31-35. 刘二保,梁建功,韩素琴,任荣芳.铬的形态分析研究与进展[J].理化检验:化学分册,2003,39(6):368-371. 陈继梅,何先莉,毛剑英.水中铬测定方法的进展[J].北京工业大学学报,2001,27(2):208-212. 梁奇峰.铬与人体健康[J].广东微量元素科学,2006,13(2):67-69. 李艳廷,李方.环境中无机铬形态分析研究进展[J].化学研究与应用,2000,12(5):476-481. 武汉大学.分析化学[M].北京:高等教育出版社,2000:156-157. 刘志钢.铬的价态对铬测定的影响[J].新疆有色金属, 2005(4):29-30. 岩石矿物分析编写组.岩石矿物分析(第一分册)[M].3版.北京:地质出版社,1991:83-86.
计量
- 文章访问数: 1479
- HTML全文浏览量: 0
- PDF下载量: 1345