氢化物发生-原子荧光光谱法测定生物样品中的硒
Determination of Selenium in Biological Samples by Hydride Generation- Atomic Fluorescence Spectrometry
-
摘要: 用硝酸-高氯酸分解生物样品,在4 mol/L盐酸介质中,加入一定浓度的三价铁盐作为掩蔽剂抑制干扰元素,用氢化物发生-原子荧光光谱法测定生物样品中微量硒的含量。方法检出限为0.02 μg/L,精密度(RSD,n=11)为1.51%。经国家一级生物标准物质验证,测定结果准确可靠。方法具有操作简单、灵敏度高、线性范围宽等优点,所用试剂毒性小,实用性强,适合广泛使用。Abstract: A method for determination of selenium in biological samples by hydride generation-atomic fluorescence spectrometry was developed. The samples were decomposed with HNO3-HClO4 and Fe3+ was used as relieving reagent in 4 mol/L HCl medium. The detection limit of the method was 0.02 μg/L. The method has been applied to the determination of selenium in biological national standard reference materials and the results are in agreement with certified values with precision of 1.51% RSD(n=11).
-
Keywords:
- atomic /
- fluorescence /
- spectrometry /
- hydride
-
-
高苹, 刘中笑. 原子荧光光谱法测定疏菜中微量硒[J].现代科学仪器, 2000(6):16-17. 中国绿色食品发展中心.绿色食品标准(内部资料)[Z].1995. 食品卫生理化检验标准手册[S].北京:中国标准出版社,1997:147-157. 北京吉天仪器有限公司.原子荧光分析方法手册[Z].2003:45. 王守兰,陈永刚.荧光光度法测定富硒米、富硒茶中痕量硒含量[J].光谱实验室, 1998,15(1):34-36. 徐宝玲,刘晓林. HG-AFS测定生物样品中Se[J].理化检验:化学分册,1984, 20(3):18-20. 栗杨.氢化物原子荧光法测定三七中的硒[J].光谱实验室,2002,19(2):209-211. 江志刚.氢化物原子荧光法测定海藻低聚糖中的硒[J].分析试验室,2002,21(3):85-87. 金永高.氢化物原子荧光法测定海产品中的硒[J].中国卫生检验杂志,2001,11(1):54-56. 徐卫红.氢化物原子荧光法测定人体血清中的硒[J].中国卫生检验杂志,2001,11(6):669-671. 彭琨.氢化物原子荧光法测定食品中的硒[J].理化检验:化学分册,2002,36(12):557-559. 张锦茂, 范凡, 任萍.氢化物-原子荧光法测定岩石中痕量硒的干扰及消除[J].岩矿测试, 1993,12(4):264-267. 杨理勤. Fe3+、碲对硒的氢化物化学干扰机理的实验研究[J].光谱学与光谱分析,1999,19(3):399-401. 柴昌信, 陈世焱, 陈月源.氢化物发生-原子荧光光谱法直接测定多金属矿中的硒和碲[J].岩矿测试, 2009,28(2):143-146. 苏文峰, 李刚.焙烧分离-氢化物发生-原子荧光光谱法测定土壤样品中的微量硒[J].岩矿测试,2008,27(2):120-122.