蒸馏分离-电感耦合等离子体质谱法测定地球化学样品中痕量钌和锇
Determination of Trace Ruthenium and Osmium in Geochemical Samples by Inductively Coupled Plasma-Mass Spectrometry with Distillation Separation
-
摘要: 建立了蒸馏分离-电感耦合等离子体质谱法测定地球化学样品中痕量钌和锇的分析方法。进行了蒸馏温度和时间、氧化剂、吸收液等条件的选择,消除了等离子体质谱法测定钌和锇的干扰。样品用过氧化钠熔融,酸化后以高锰酸钾-过硫酸钾-氯化钠作为同时蒸馏钌和锇的氧化剂,采用20 mL 50 g/L水合肼溶液同时吸收从混合物中分离出来的痕量钌和锇,用电感耦合等离子体质谱法测定。方法的检出限Ru为0.020 ng/g,Os为0.015 ng/g;方法加标回收率Ru为94.0%~102.7%,Os为96.0%~102.4%;精密度为4.72%~9.58% (n=12)。方法经国家一级标准物质验证,钌和锇的测定结果与标准值相符。
-
关键词:
- 蒸馏分离 /
- 电感耦合等离子体质谱法 /
- 钌 /
- 锇 /
- 地球化学样品
Abstract: An inductively coupled plasma-mass spectrometric (ICP-MS) method for determination of trace ruthenium and osmium in geochemical samples with distillation separation was established. The elimination of the interferences on ICP-MS measurements were studied through the experiments. Samples were decomposed with Na2O2 fusion method and the melts were dissolved with acid solution. KMnO4+K2S2O4+NaCl were added to the sample solution as an oxidant and 20 mL 5% hydrazine hydrate was selected as an absorbent. Trace ruthenium and osmium in the sample solution were separated by distillation from matrix and determined by ICP-MS. Distillation conditions, such as temperature, time, oxidant and absorbent were tested and optimized. The detection limits of the method were 0.020 ng/g for Ru and 0.015 ng/g for Os. Recoveries of the method were 94.0%~102.7% for Ru and 96.0%~102.4% for Os with precision of 4.72%~9.58%RSD(n=12) for both elements. The reliability of the method has been tested by determination of trace Ru and Os in National Standard Reference materials and the results are in agreement with the certified values.-
Keywords:
- distillation /
- separation /
- inductively /
- coupled /
- plasma-mass
-
-
宋学省,崔玉理.Ru(Ⅲ)-孔雀绿-高氯酸钾体系催化光度法测定痕量钌[J].冶金分析,2008,28(5):51-53. Zhou Z R, Wang Q, Zhang S Y. Kinetic spectro-photometric determination of trace ruthenium(Ⅲ) based on catalytic effect of ruthenium(Ⅲ) on oxidation of acid chrome blue K by potassium bromate[J].Metallurgical Analysis, 2007,27(7):13-19. Zhou Z R, Wang Q, Zhang S Y. Kinetic spectro-photometric determination of trace ruthenium(Ⅲ) based on catalytic effect of ruthenium(Ⅲ) on oxidation of acid chrome blue K by potassium bromate[J].Metallurgical Analysis, 2007,27(7):13-19.
林秋华.固绿FCF催化动力学光度法测定痕量钌[J].分析试验室,2007,26(2):60-62. 杨志毅,郭洁,杜建华,赵霞,李珍贵.吖啶红-高碘酸钾催化光度法测定痕量钌[J].分析试验室,2006,25(2):10-12. 曹秋娥,李祖碧,李崇宁,王加林.锇与偶氮胭脂红B和高碘酸钾催化反应的研究及分析应用[J].理化检验:化学分册,2002,38(8):384-386. 缪吉根,吴小华,蔡汝秀.锇(Ⅳ)催化抗坏血酸还原三溴偶氮胂的褪色反应特性及痕量锇的测定[J].分析化学,2002,30(4):443-446. 黄章杰,胡秋芬,尹家元,徐其亨.催化动力学分光光度法测定痕量锇[J].分析化学,2001,29(12):1437-1439. 陈吉书,侯能邦,徐其亨.二安替比林间溴苯基甲烷-高碘酸钾体系动力学光度法测定钌[J].岩矿测试,1999,18(4):288-290. 廖玲秀,蒋治良,覃诚真.催化反应-示波极谱法测定超痕量锇[J].贵金属,1994,15(4):35-38. 马配学,侯泉林,毛雪瑛,柴之芳,欧阳宝.地质样品中超痕量铂族元素的中子活化分析[J].岩矿测试,1995,14(3):208-212. 李晓林,Ebihara M.铂族元素中子活化分析的微型镍锍试金预富集方法研究[J].岩矿测试,2005,24(3):167-170. 孙亚莉,孙敏,巩爱华.小锍试金铂族元素富集方法[J].分析化学,2000,28(8):1010-1012. 何红蓼,吕彩芬,周肇茹,史世云,李冰.锍镍试金-等离子体质谱法测定地球化学勘探样品中的铂族元素和金 Ⅰ.分析流程的简化[J].岩矿测试,2001,20(3):191-194. 杨竞红,蒋少涌, Brugmann G.岩石样品中低含量铂族元素和锇同位素比值的高精度测量方法[J].岩石学报,2001,17(2):325-331. 屈文俊,杜安道.电感耦合等离子体质谱法测定辉钼矿中Re、Os含量质量分馏效应的校正[J].质谱学报,2004,25(增刊):181-182. 漆亮,周美夫,严再飞,皮道会,胡静.改进的卡洛斯管溶样等离子体质谱法测定地质样品中低含量铂族元素及铼的含量[J].地球化学,2006,35(6):667-674. 石贵勇,孙晓明,屈文俊,薛婷,张美,熊德信,王生伟.锍镍试金-电感耦合等离子体质谱法测定西太平洋富钴结壳中的铂族元素[J].岩矿测试,2007,26(2):113-116. 蔡树型,黄超.贵金属分析[M].北京:冶金工业出版社,1984:91-92,162-168. 李冰,杨红霞.电感耦合等离子体质谱原理和应用[M].北京:地质出版社,2005:156-168.
计量
- 文章访问数: 1638