• 中文核心期刊
  • 中国科技核心期刊
  • CSCD来源期刊
  • DOAJ 收录
  • Scopus 收录

密闭溶样-电感耦合等离子体质谱法测定煅烧高岭土中微量重金属元素

邵坤, 何启生, 陈开旭, 邵鑫, 程先忠

邵坤, 何启生, 陈开旭, 邵鑫, 程先忠. 密闭溶样-电感耦合等离子体质谱法测定煅烧高岭土中微量重金属元素[J]. 岩矿测试, 2010, 29(1): 43-46.
引用本文: 邵坤, 何启生, 陈开旭, 邵鑫, 程先忠. 密闭溶样-电感耦合等离子体质谱法测定煅烧高岭土中微量重金属元素[J]. 岩矿测试, 2010, 29(1): 43-46.
SHAO Kun, HE Qisheng, CHEN Kaixu, SHAO Xin, CHENG Xianzhong. Determination of Trace Heavy Metal Elements in Caclined Kaoline by Inductively Coupled Plasma-Mass Spectrometry with Pressurized Acid Digestion[J]. Rock and Mineral Analysis, 2010, 29(1): 43-46.
Citation: SHAO Kun, HE Qisheng, CHEN Kaixu, SHAO Xin, CHENG Xianzhong. Determination of Trace Heavy Metal Elements in Caclined Kaoline by Inductively Coupled Plasma-Mass Spectrometry with Pressurized Acid Digestion[J]. Rock and Mineral Analysis, 2010, 29(1): 43-46.

密闭溶样-电感耦合等离子体质谱法测定煅烧高岭土中微量重金属元素

基金项目: 

湖北省科技厅自然科学基金重点项目资助 (2008CDA100)

Determination of Trace Heavy Metal Elements in Caclined Kaoline by Inductively Coupled Plasma-Mass Spectrometry with Pressurized Acid Digestion

  • 摘要: 建立了密闭溶样-电感耦合等离子体质谱法同时测定煅烧高岭土中铜、铅、锌、铬、镉和锰等6个微量重金属元素的有效方法。实验中对仪器的最佳工作参数进行了优化,选择适当的同位素,并用铑作内标元素,有效地抑制了分析信号的漂移以及分子和多原子离子的质谱干扰;探讨了混合酸消解体系、消解液用量、密闭溶样的时间对测定结果的影响。以硝酸-氢氟酸作为消化试剂,在180℃下溶解4 h能完全消解样品。在选定的实验条件下,对煅烧高岭土样品进行了精密度和回收率试验,方法相对标准偏差(RSD,n=9)为0.96%~2.22%,加标回收率为98.0%~101.5%。
计量
  • 文章访问数:  1776
  • HTML全文浏览量:  0
  • PDF下载量:  1347
  • 被引次数: 0
出版历程
  • 收稿日期:  2009-06-05
  • 修回日期:  2009-09-14

目录

    /

    返回文章
    返回