• 中文核心期刊
  • 中国科技核心期刊
  • CSCD来源期刊
  • DOAJ 收录
  • Scopus 收录

无载气氢化物发生-石英缝管捕集原子吸收光谱法测定地质试样中的铋

褚人才, 陈恒武, 吴德秀

褚人才, 陈恒武, 吴德秀. 无载气氢化物发生-石英缝管捕集原子吸收光谱法测定地质试样中的铋[J]. 岩矿测试, 1994, (4): 298-301.
引用本文: 褚人才, 陈恒武, 吴德秀. 无载气氢化物发生-石英缝管捕集原子吸收光谱法测定地质试样中的铋[J]. 岩矿测试, 1994, (4): 298-301.
Atomic Absorption Spectrometric Determination of Bismuth in Geological Samples Using Non Carrier-gas Hydride Generation in Conjunction with Slotted Tube Atom Trap Technique[J]. Rock and Mineral Analysis, 1994, (4): 298-301.
Citation: Atomic Absorption Spectrometric Determination of Bismuth in Geological Samples Using Non Carrier-gas Hydride Generation in Conjunction with Slotted Tube Atom Trap Technique[J]. Rock and Mineral Analysis, 1994, (4): 298-301.

无载气氢化物发生-石英缝管捕集原子吸收光谱法测定地质试样中的铋

Atomic Absorption Spectrometric Determination of Bismuth in Geological Samples Using Non Carrier-gas Hydride Generation in Conjunction with Slotted Tube Atom Trap Technique

  • 摘要: 文章介绍石英缝管原子捕集技术在氢化物-火焰原子吸收光谱法测定Bi中的应用。采用自制的无载气氢化物发生装置,对实验条件进行了最佳化。实验结果表明,原子捕集技术的应用使氢化物-火焰原子吸收法的灵敏度提高2.2倍;方法检出限(3σ)达2.5ng;20ng/mlBi的标准溶液10次测定的RSD为2.9%。方法用于地质标样中微量Bi的测定,结果与推荐值符合。
计量
  • 文章访问数:  1791
  • HTML全文浏览量:  0
  • PDF下载量:  926
  • 被引次数: 0
出版历程

目录

    /

    返回文章
    返回